Mouse IgG3 ELISA Kit

Catalog No.: BEK1298
Size: 96T
Range: 1.56 ng/ml - 100 ng/ml
Sensitivity < 0.22 ng/ml
Application: For quantitative detection of IgG3 in mouse serum, plasma, body fluids, tissue lysates or cell culture supernatants.
--------------------------------------------------------------------------------------------------------------
Price: $360.00

  


Catalog No.: BEK1298


Size: 96T


Range: 1.56 ng/ml - 100 ng/ml


Sensitivity < 0.22 ng/ml


Storage and Expiration: Store at 2-8℃ for 6 months, or at -20 for 12 months. 


Application: For quantitative detection of IgG3 in mouse serum, plasma, body fluids, tissue lysates or cell culture supernatants.


Introduction

Ig gamma-3 chain C region is a protein that in humans is encoded by the IGHG3 gene.


Principle of the Assay  

This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti- IgG3 polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti- IgG3 polyclonal antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the IgG3 amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of IgG3 can be calculated.


Kit components

  1. One 96-well plate pre-coated with anti-mouse IgG3 antibody
  2. Lyophilized mouse IgG3 standards: 2 tubes (100ng / tube)                     
  3. Sample / Standard diluent buffer: 30ml
  4. Biotin conjugated anti-mouse IgG3 antibody (Concentrated): 130μl. Dilution: 1:100
  5. Antibody diluent buffer: 12ml
  6. Avidin-Biotin-Peroxidase Complex (ABC) (Concentrated): 130μl. Dilution: 1:100
  7. ABC diluent buffer: 12ml
  8. TMB substrate: 10ml
  9. Stop solution: 10ml
  10. Wash buffer (25X): 30ml

Note: Reconstitute standards and test samples with Kit Component 3.


Material Required But Not Provided

  1. 37℃ incubator
  2. Microplate reader (wavelength: 450nm)
  3. Precise pipette and disposable pipette tips
  4. Automated plate washer
  5. ELISA shaker
  6. 1.5ml of Eppendorf tubes
  7. Plate cover
  8. Absorbent filter papers
  9. Plastic or glass container with volume of above 1L

Details