Human TIMP-3 ELISA Kit
Size: 96T
Range: 156 pg/ml-10,000 pg/ml
Sensitivity < 2 pg/ml
Application: For quantitative detection of TIMP-3 in human serum, plasma, body fluids, tissue lysates or cell culture supernatants.
--------------------------------------------------------------------------------------------------------------
Price: $360.00
Catalog No.: BEK1211
Size: 96T
Range: 156 pg/ml-10,000 pg/ml
Sensitivity < 2 pg/ml
Storage and Expiration: Store at 2-8℃ for 6 months, or at -20℃ for 12 months.
Application: For quantitative detection of TIMP-3 in human serum, plasma, body fluids, tissue lysates or cell culture supernatants.
Introduction
Metalloproteinase inhibitor 3 is an protein that in humans is encoded by the TIMP3 gene, which maps to to chromosome 22. This gene belongs to the tissue inhibitor of metalloproteinases gene family. The proteins encoded by this gene family are inhibitors of the matrix metalloproteinases, a group of peptidases involved in degradation of the extracellular matrix (ECM). Expression of this gene is induced in response to mitogenic stimulation and this netrin domain-containing protein is localized to the ECM. The balance of MMP and TIMP determines the net migratory capacity of DCs. Mutations in this gene have been associated with the autosomal dominant disorder Sorsby's fundus dystrophy.
Principle of the Assay
This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti-TIMP-3 polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-TIMP-3 polyclonal antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the TIMP-3 amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of TIMP-3 can be calculated.
Kit components
- One 96-well plate pre-coated with anti-Human TIMP-3 antibody
- Lyophilized Human TIMP-3 standards: 2 tubes (10 ng / tube)
- Sample / Standard diluent buffer: 30ml
- Biotin conjugated anti-Human TIMP-3 antibody (Concentrated): 130μl. Dilution: 1:100
- Antibody diluent buffer: 12ml
- Avidin-Biotin-Peroxidase Complex (ABC) (Concentrated): 130μl. Dilution: 1:100
- ABC diluent buffer: 12ml
- TMB substrate: 10ml
- Stop solution: 10ml
- Wash buffer(25X): 30ml
Note: Reconstitute standards and test samples with Kit Component 3.
Material Required But Not Provided
- 37℃ incubator
- Microplate reader (wavelength: 450nm)
- Precise pipette and disposable pipette tips
- Automated plate washer
- ELISA shaker
- 1.5ml of Eppendorf tubes
- Plate cover
- Absorbent filter papers
- Plastic or glass container with volume of above 1L